7313242 (Rev. M 7/1/13)NSRO42C4Manufactured and warranted byEcodyne Water Systems LLC1890 Woodlane DriveWoodbury, MN 55125Installation and Operation
10Step B - Install RO Drain Under SinkINTRODUCTIONA suitable drain point is needed for the drain water fromthe Reverse Osmosis Filter. You have two op
11Step B - Install RO Drain In Remote Location INSTALL A REMOTE DRAIN POINT AND AIR GAP (Remote Location)Route the drain tubing to an existing drain i
12Step C: Install RO Filter AssemblyINSTALL REVERSE OSMOSIS FILTER ASSEMBLYThe Reverse Osmosis Filter Assembly is mounted onhanger washers. See Fig 13
13Step D - Install Storage TankThe fitting on the supply tank may need to be tightened7-8 full turns to get a good seal.Do not overtighten.INSTALL STO
14Step E: Install RO FaucetINSTALL BATTERYWhen the coin battery is first applied at initial start up,the LED indicator light will flash in red, amber,
15Step E: Install RO Faucet (cont.)BLACK TUBE3/8” barb fittingfor the black tubeRED TUBE1/4” barb fitting for the red tubeBLUE TUBE3/8” quick connect
16Step F - Connect TubesHOW TO CUT AND CONNECT THE TUBESYour Reverse Osmosis system includes push-in fittingsfor quick tubing connection. Review the f
17Step F - Connect Tubes (cont.)ROUTE YELLOW TUBE TO STORAGE TANK1. Locate the yellow tube attached to the Reverse Osmosis filter assembly. 2. Route t
18Step G - Sanitize, Test and Purge SystemSANITIZE THE SYSTEMSanitizing is recommended immediately after installa-tion of the Reverse Osmosis system.
19Step G - Sanitize, Test and Purge System (cont.)PRESSURE TEST THE SYSTEMNOTE: Complete the sanitizing procedures on thepreceding page before pressur
2Questions?Visit www.northstarconditioning.comor call Toll Free1-800-972-0135Monday- Friday, 7 AM - 6 PM CSTWhen you call, please be prepared to provi
20How Your RO Water System WorksINTRODUCTION: Your Reverse Osmosis (RO)Drinking Water System uses your household waterpressure to force water through
21How Your RO Water System WorksWater Flow Description1. Water enters prefilter. Sand, silt and other sediments are reduced. Chlorine is also reduced.
22MaintenancePREFILTER/POSTFILTER MAINTENANCENOTE: It is recommended to replace the battery,prefilter and postfilter cartridges at least every 6months
23MaintenanceFLOW CONTROL The flow control is required for proper operation of theReverse Osmosis system. See Fig. 30. The flow con-trol, located insi
24TroubleshootingProblem: Chlorine taste and/or odor in the RO product water.Cause: The level of chlorine in your water supplyexceeds maximum limits,
25TroubleshootingProblem: Water leaking from faucet airgap hole.Cause: Drain side of faucet airgap (3/8” black tub-ing) plugged, restricted or incorre
26Exploded View28272624232221201/4” redtubing18131097645312251116171519814126
27¢ Not illustrated.= Not included.p Tubing lengths for remote installations, direct replacement for colored lengths of tubing.NOTE: Codes in the stat
28- PARTS RETURN TAGS -If you have a defective part or assembly under warranty, please fill in a parts return tag. Cut out thetag and include it with
3ONE YEAR LIMITED WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM(Except filter cartridges and R.O. membrane)Warrantor: North Star Water Conditionin
4Supply water pressure limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-100 psi (280-689 kPa)Sup
5NOTE: Codes in the state of Massachusetts requireinstallation by a licensed plumber and do not per-mit the use of saddle valves. If you live in the s
6PLAN YOUR INSTALLATIONRead through the entire manual before beginningyour installation. Follow all steps exactly. Reading thismanual will also help y
7Typical Under Sink InstallationTypical Remote InstallationHard Water LineAll install parts included in package.Additional Parts required.Plan Your In
8OVERVIEWRead through the entire manual before beginning yourinstallation.There are seven steps to installing your Drinking Water system. They are as
9Cold Water Supply Fitting(Included in package)Use to ConnectTubing1/4” green tubingto ReverseOsmosis inletwater supply fitting(tee feed adaptor)cold
Komentarze do niniejszej Instrukcji