7313242 (Rev. M 7/1/13)
NSRO42C4
Manufactured and warranted by
Ecodyne Water Systems LLC
1890 Woodlane Drive
Woodbury, MN 55125
Installation and Operation Manual
System tested and certified by NSF International
against NSF/ANSI Standards 42 & 58.
See performance data sheet for details.
If you have any questions or concerns when
installing, operating or maintaining your reverse
osmosis system, call our toll free number:
1-800-972-0135
Monday- Friday, 7 AM - 6 PM CST
(in Canada please call
1-800-796-6784)
or visit www.northstarconditioning.com
When you call, please be prepared to provide
the model, date code and serial number of your
product, found on the rating decal, located
inside the cover.
How to Install, operate and
maintain your Reverse Osmosis
Drinking Water System
Designed, Engineered &
Assembled in the U.S.A.
Przeglądanie stron 0
1 2 3 4 5 6 ... 27 28

Podsumowanie treści

Strona 1 - NSRO42C4

7313242 (Rev. M 7/1/13)NSRO42C4Manufactured and warranted byEcodyne Water Systems LLC1890 Woodlane DriveWoodbury, MN 55125Installation and Operation

Strona 2 - Questions?

10Step B - Install RO Drain Under SinkINTRODUCTIONA suitable drain point is needed for the drain water fromthe Reverse Osmosis Filter. You have two op

Strona 3 - Warranty

11Step B - Install RO Drain In Remote Location INSTALL A REMOTE DRAIN POINT AND AIR GAP (Remote Location)Route the drain tubing to an existing drain i

Strona 4 - 16"

12Step C: Install RO Filter AssemblyINSTALL REVERSE OSMOSIS FILTER ASSEMBLYThe Reverse Osmosis Filter Assembly is mounted onhanger washers. See Fig 13

Strona 5 - Unpack and Check Your Carton

13Step D - Install Storage TankThe fitting on the supply tank may need to be tightened7-8 full turns to get a good seal.Do not overtighten.INSTALL STO

Strona 6 - Plan Your Installation

14Step E: Install RO FaucetINSTALL BATTERYWhen the coin battery is first applied at initial start up,the LED indicator light will flash in red, amber,

Strona 7

15Step E: Install RO Faucet (cont.)BLACK TUBE3/8” barb fittingfor the black tubeRED TUBE1/4” barb fitting for the red tubeBLUE TUBE3/8” quick connect

Strona 8 - Overview and Site Preparation

16Step F - Connect TubesHOW TO CUT AND CONNECT THE TUBESYour Reverse Osmosis system includes push-in fittingsfor quick tubing connection. Review the f

Strona 9 - (Included in package)

17Step F - Connect Tubes (cont.)ROUTE YELLOW TUBE TO STORAGE TANK1. Locate the yellow tube attached to the Reverse Osmosis filter assembly. 2. Route t

Strona 10 - Under The Sink Installation

18Step G - Sanitize, Test and Purge SystemSANITIZE THE SYSTEMSanitizing is recommended immediately after installa-tion of the Reverse Osmosis system.

Strona 11 - Installation

19Step G - Sanitize, Test and Purge System (cont.)PRESSURE TEST THE SYSTEMNOTE: Complete the sanitizing procedures on thepreceding page before pressur

Strona 12 - ASSEMBLY

2Questions?Visit www.northstarconditioning.comor call Toll Free1-800-972-0135Monday- Friday, 7 AM - 6 PM CSTWhen you call, please be prepared to provi

Strona 13 - Step D - Install Storage Tank

20How Your RO Water System WorksINTRODUCTION: Your Reverse Osmosis (RO)Drinking Water System uses your household waterpressure to force water through

Strona 14 - Step E: Install RO Faucet

21How Your RO Water System WorksWater Flow Description1. Water enters prefilter. Sand, silt and other sediments are reduced. Chlorine is also reduced.

Strona 15

22MaintenancePREFILTER/POSTFILTER MAINTENANCENOTE: It is recommended to replace the battery,prefilter and postfilter cartridges at least every 6months

Strona 16 - Step F - Connect Tubes

23MaintenanceFLOW CONTROL The flow control is required for proper operation of theReverse Osmosis system. See Fig. 30. The flow con-trol, located insi

Strona 17 - 3/8” BLUE

24TroubleshootingProblem: Chlorine taste and/or odor in the RO product water.Cause: The level of chlorine in your water supplyexceeds maximum limits,

Strona 18 - SANITIZE THE SYSTEM

25TroubleshootingProblem: Water leaking from faucet airgap hole.Cause: Drain side of faucet airgap (3/8” black tub-ing) plugged, restricted or incorre

Strona 19 - PRESSURE TEST THE SYSTEM

26Exploded View28272624232221201/4” redtubing18131097645312251116171519814126

Strona 20 - Reset Button

27¢ Not illustrated.= Not included.p Tubing lengths for remote installations, direct replacement for colored lengths of tubing.NOTE: Codes in the stat

Strona 21

28- PARTS RETURN TAGS -If you have a defective part or assembly under warranty, please fill in a parts return tag. Cut out thetag and include it with

Strona 22 - Maintenance

3ONE YEAR LIMITED WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM(Except filter cartridges and R.O. membrane)Warrantor: North Star Water Conditionin

Strona 23

4Supply water pressure limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-100 psi (280-689 kPa)Sup

Strona 24 - Troubleshooting

5NOTE: Codes in the state of Massachusetts requireinstallation by a licensed plumber and do not per-mit the use of saddle valves. If you live in the s

Strona 25

6PLAN YOUR INSTALLATIONRead through the entire manual before beginningyour installation. Follow all steps exactly. Reading thismanual will also help y

Strona 26 - Exploded View

7Typical Under Sink InstallationTypical Remote InstallationHard Water LineAll install parts included in package.Additional Parts required.Plan Your In

Strona 27 - Parts List

8OVERVIEWRead through the entire manual before beginning yourinstallation.There are seven steps to installing your Drinking Water system. They are as

Strona 28 - - PARTS RETURN TAGS

9Cold Water Supply Fitting(Included in package)Use to ConnectTubing1/4” green tubingto ReverseOsmosis inletwater supply fitting(tee feed adaptor)cold

Komentarze do niniejszej Instrukcji