Ecodyne Water Systems TB-30 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Dozowniki wody Ecodyne Water Systems TB-30. Ecodyne Water Systems TB-30 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
How to install, operate
and maintain your Demand
Controlled Water Softener
Model TB-30
Installation and Operation Manual
7330189 (Rev. C 8/16/11)
Systems tested and certified by NSF International
against NSF/ANSI Standard 44
for hardness reduction and efficiency.
Printed on recycled paper
TM
If you have any questions about system
programming, operation or maintenance,
call toll free:
1-800-689-4571
Monday - Friday, 8:30 am - 6:00 pm EST
or Saturday 9:00 am - 3:00 pm EST
or visit us online at:
www.truebluewatersolutions.com
When you call, please be prepared to provide
the model, date code and serial number of your
product, found on the rating decal, located on
the back of the controller top cover.
Manufactured for Defender Security Company by
Ecodyne Water Systems
1890 Woodlane Drive
Woodbury, MN 55125
Przeglądanie stron 0
1 2 3 4 5 6 ... 22 23

Podsumowanie treści

Strona 1 - Model TB-30

How to install, operateand maintain your DemandControlled Water SoftenerModel TB-30Installation and Operation Manual7330189 (Rev. C 8/16/11)Systems t

Strona 2 - TABLE OF CONTENTS

10Installation Instructions10. ADD WATER AND SALT TO THE SALTSTORAGE TANK1. Using a container, add about three gallons of cleanwater into the salt sto

Strona 3

11Programming the Electronic ControllerCONTROLLER SETTINGS REQUIREDupon installation, and after an extended power outage.When the transformer is plugg

Strona 4 - Inspect Shipment

12OPTIONAL RECHARGE CONTROLSSometimes a manually initiated regeneration (re -charge) may be desired or needed. Two examples:= You have used more wate

Strona 5 - Installation Requirements

13OPTIONAL SETTINGS:= SALT EFFICIENCY= MAXIMUM DAYS BETWEEN REGEN-ERATIONS= 97% FEATURE= 12 / 24 HOUR CLOCK= BACKWASH & FAST RINSE TIMES1. To set

Strona 6 - FIG. 5FIG. 5

14Controller Features / Options4. Press SELECT again to display the “12 or 24 hr”screen.If you wish to change the fast rinse time, use theUP ( ) or DO

Strona 7

15FIG. 33BroomHandlePencilMark1” - 2”SaltSalt BridgeWater LevelPush tool intosalt bridge tobreakFIG. 34CapO-ring SealScreen SupportScreenGasket*Flow P

Strona 8

16Troubleshooting GuidePROBLEM CAUSE CORRECTIONNo soft water No salt in the storage tank. Add salt and then initiate a “Recharge Now”.Salt is “bridged

Strona 9

17TroubleshootingAUTOMATIC ELECTRONIC DIAGNOSTICSThe electronic controller has a self-diagnostic functionfor the electrical system (except input power

Strona 10 - Installation Instructions

18Troubleshooting6. Press the SELECT button and hold in for 3 sec-onds until the model code (tb-30) shows in the dis-play. This code identifies the s

Strona 11

19 24 VACTransformerTurbineSensorOUTGND+5PositionSwitchNONCgrnbrnValveMotorBack of Controller (PWA)AC INPUTPOS. / TURBINEMOTORTroubleshootingWIRING SC

Strona 12

2TABLE OF CONTENTSPageSpecifications & Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 13 - Controller Features / Options

201Valve AssemblySee Pages 22 & 23for parts234567891011121314151617221819202128292324252630313233343536Softener Exploded View (Model TB-30)27

Strona 14

21KeyNo.Part No. Description1 7112971 Shroud2 7026196 Base3 7176292 Clamp Section (2 req.)4 7088033 Retainer Clip (2 req.)5 7112963O-Ring Seal Kit,inc

Strona 15 - Routine Maintenance

22Valve Exploded View (Model TB-30)505152535455565758596061626364656667 68697071Wear StripSealCross-sectionView747273757676787981808283848586878889909

Strona 16 - Troubleshooting Guide

23Valve Parts List (Model TB-30)KeyNo.Part No. Description50 7070412 Screw, #4-24 x 1-1/8”, flat head51 7325702 Spacer, Motor Mount52 7030713 Switch53

Strona 17 - Troubleshooting

3Specifications & DimensionsModel TB-30Model Code tb-30Rated Softening Capacity (Grains @ Salt Dose)11,800 @ 2.3 lbs.25,300 @ 7.4 lbs.30,200 @ 12.

Strona 18

4Packing ListInspect ShipmentGround ClampKit20 ft. Drain HoseBypass Valve ClipsAdaptor ElbowInstallationAdaptorsFIG. 2Hose ClampsGrommetThe parts requ

Strona 19

5PLUMBING CODESAll plumbing must be completed in accordance withnational, state and local plumbing codes.LAUNDRY TUBSTANDPIPE1-1/2”air gapFLOOR DRAINA

Strona 20 - (Model TB-30)

6Typical Installation IllustrationsFIG. 5FIG. 5120 VoltOutletSoftWaterHardWaterHard Water tooutside faucetsCROSSOVERUse if water supply flows from the

Strona 21

7Installation Instructions1. TURN OFF WATER SUPPLYa. Close the main water supply valve near the wellpump or water meter.b. Shut off the electric or fu

Strona 22

84. COMPLETE INLET AND OUTLETPLUMBINGPipe fittings must be 3/4” minimum.Use:= Copper pipe= Threaded pipe= PEX (Crosslinked Polyethylene) pipe= CPVC pl

Strona 23

98. CONNECT BRINE TUBINGa. Route the tubing attached to the brine valve assem-bly out of the brine tank through the hole provided inthe tank sidewall.

Komentarze do niniejszej Instrukcji